model |
K2 |
K4 |
K6 |
|
Cabinet type, integrated, automated on-site hydrogen production. |
||
Electrolyte |
|||
|
Proton Exchange Membrane (PEM)-non-corrosive |
||
Hydrogen production |
|
||
Hydrogen production |
2 Nm3/h |
4 Nm3/h |
6 Nm3/h |
Rated output pressure |
15 barg (218 psig) / 30 barg optional (435 psig) |
||
Energy consumption/NM3 hydrogen |
7.3 kWh/Nm3 |
7.0 kWh/Nm3 |
6.8 kWh/Nm3 |
Purity (impurity content) |
99.9995% (water vapor <5 ppm, -65°C dew point, N2 <2 ppm, O2 <1 ppm, other components are not detected) |
||
Adjustment range |
0 to 100% hydrogen production (automatic adjustment) |
||
Upgradeable range |
Can be upgraded to 6 Nm3/hr (228 SCF/hr) on site |
Can't upgrade |
|
Deionized water parameters |
|||
Maximum consumption |
1.83 L/hr |
3.66 L/hr |
5.50 L/hr |
temperature |
5°C to 50°C / 41°F to 122°F |
||
pressure |
1.5 to 4 barg / 21.8 to 58.0 psig |
||
Water quality requirements |
ASTM II type deionized water, <1 micros/cm (> 1 MegOhm-cm) ASTM I type deionized water, <0.1 micros/cm (> 10 MegOhm-cm) is recommended |
||
Thermal load and cooling parameters |
|||
cool down |
Liquid cooling; antifreeze, antifouling; 5°C to 35°C (41°F to 95°F) when the |
||
Maximum heat load (cooling parameter) |
8.1 kW 27,368 BTU/hr |
16.1 kW 58,36 BTU/hr |
23.7 kW 80,868 BTU/hr |
Coolant flow |
Up to 45 L/min (12 gal/min) |
Up to 68 L/min (18 gal/min) |
Up to 87 L/min (23 gal/min) |
Pressure loss (full load) |
Up to ~3.4 barg (~50 psig) |
Up to ~3.4 barg (~50 psig) |
Up to ~3.4 barg (~50 psig) |
Electrical Specifications |
|||
Recommended circuit breaker rating |
22 kVA |
38 kVA |
55 kVA |
Electrical parameters |
480 VAC, 3 phase, 60 Hz or 380-415 VAC, 3 phase, 50 Hz |
|
K2 |
K4 |
K6 |
||
Interface connection-For more information, please refer to the mechanical interface diagram, PD-9900-0003- |
|||||
氢气接口 |
1/4” Parker CPITM 不锈钢压缩管接口 |
||||
氢气/水 排空接口 |
1/2” FNPT, 不锈钢 |
||||
去离子水接口 |
1/4” FNPT, 不锈钢 |
||||
校准气体接口 |
1/8” FNPT, 铜 |
||||
冷却水供应接口 |
1” FNPT, 铜 |
||||
冷水水回流接口 |
1” FNPT, 铜 |
||||
排水口 |
3/8” FNPT, 铜 |
||||
电气 |
与控制板上铜断路器连接 |
||||
通讯 |
以太网 |
||||
控制系统 |
|
||||
标准配置 |
|
|
|||
远程报警 |
C型继电器, 5A, 250V, 150W 最大. 额定 |
||||
远程关机 |
安全电路跳闸 |
||||
外机参数 |
|||||
尺寸, W x D x H |
产品 |
71” x 32 “ x 75” / 180 cm x 81 cm x 191 cm |
|||
重量 |
产品 |
1500 lbs / 682 kg |
1600 lbs / 727 kg |
1700 lbs / 773 kg |
|
防护等级 |
IP66 适用于电气间. IP43 for工艺间;升级至IP56. |
||||
环境要求 – 防冻 |
|||||
选址标准 |
室内, 水平±1°,相对湿度0至90%,无凝结, |
||||
储存/运输温度 |
5°C to 60°C / 41°F to 140°F |
||||
环境温度范围 |
5°C to 50°C / 41°F to 122°F |
||||
纬度范围- 海平面 |
2400 m / 7874 ft |
||||
通风 |
非危险区域须提供适当的通风,其通风速率应符合IEC60079-10,区域2 NE |
||||
安全和监管 |
|||||
Maximum storage capacity of hydrogen in the pipeline at full production rate |
0.040 Nm3 @ 15 barg; 0.08 Nm3 @ 30 barg |
||||
Cabinet ventilation environment |
NFPA 69 and EN 1127-1, Article 6.2. |
||||
Noise at 1 meter dB(A) |
<83 |
||||
specification |
cTUVus (UL and CSA equivalent), CE (PED, ATEX, LVD, Mach. Dir., EMC), NYFD |
Related Products
© 2007-2021 Shenzhen Kylin Technology Co., Ltd All rights reserved.
粤ICP备2021071683号 Powered by www.300.cn
Room 2209-2210, East Block, China Power Information Building, No. 1 Xinwen Road, Futian District, Shenzhen