undefined
+
  • undefined

PEM Small and Medium Electrolysis Equipment


Key words:



●Cabinet type, integrated, automated on-site hydrogen production.
● After operation, the hydrogen production can be automatically matched according to the demand parameters.
● Interface connection-For details, refer to the mechanical interface diagram, PD-9900-0003-

Product Description

Small and Medium PEM Electrolysis Equipment

2-10NM3/hr

Based on configuration requirements and operating conditions, product specifications can be changed and customized. Please contact Kylin to obtain the most suitable solution for your needs.

 

  K2 K4 K6
Electrolyte Proton exchange membrane (PEM) -non-corrosive
hydrogen production  
hydrogen production 2 Nm3/h 4 Nm3/hour 6 Nm3/hour
Nm3/hr @ 0 °C, 1 bar SCF/hr @ 21 °C, 76 SCF/h 152 SCF/hour 228 SCF/hour
1 atm SLPM @21°C, 1 atm 35.8 SLPM 71.7 SLPM 107.6 SLPM
kg /24 hours 4.31kg/24 hours 8.63kg/24 hours 12.94kg/24 hours
Rated output pressure 15 barg (218 psig) / 30 barg 可选 (435 psig)
Energy consumption/NM3 hydrogen 7.3 kWh/Nm3 7.0 kWh/Nm3 6.8 kWh/Nm3
Purity (impurity content) 99.9995% (water vapor <5 ppm, -65°C dew point, N2 < 2 ppm, O2 < 1 ppm, other components not detected)
Adjustment range 0 to 100% hydrogen production (automatic regulation)
Upgradeable Scope Field upgradeable to 6 Nm3/hr (228 SCF/hr) Unable to upgrade
Deionized water parameters  
Maximum consumption 1.83 L/hr 3.52L/hr 5.2 L/hr
0.50 gal/hr 0.96 gal/hr 1.42 gal/hr
Temperature 5°C to 50°C / 41°F to 122°F
Pressure 1.5 to 4 barg / 21.8 to 58.0 psig
Water Quality Requirements ASTM Type II deionized water, <1 micros/cm (> 1 MegOhm-cm) recommend ASTM Type I deionized water, <0.1 micros/cm (> 10 MegOhm-cm)
Heating load and cooling parameters  
Cooling Liquid cooling; antifreeze, antifouling; 5°C to 35°C (41 °F to 95 °F)
The maximum cooling water temperature is 25°C when the ambient temperature is higher than 40°C
Maximum heat load (cooling parameter) 8.1 kW 27.368 BTU/hr 16.1 kW 54.936 BTU/hr 23.7 kW 80.868 BTU/hr
Coolant flow 达 45 L/min (12 gal/min) 达68 L/min (18 gal/min) 达87 L/min (23 gal/min)
Pressure loss (full load) 达 ~3.4 barg (~50 psig) 达 ~3.4 barg (~50 psig) 达 ~3.4 barg (~50 psig)
Electrical Specifications  
recommend circuit breaker rating 22 kVA 38 kVA 55 kVA
Electrical parameters 480 VAC, 3 phase, 60 Hz gold 380-415 VAC, 3 phase, 50 Hz

 

  K2 K4 K6
Hydrogen interface 1/4 "Parker CPITM Stainless Steel Compression Tube Interface
Hydrogen/water exhaust interface 1/2 "FNPT, stainless steel
Deionized water interface 1/4 "FNPT, stainless steel
Calibration gas interface 1/8 "FNPT, Copper
Cooling water supply interface 1 "FNPT, Copper
Cold water return interface 1 "FNPT, Copper
Drain 3/8 "FNPT, Copper
Electrical Connect with copper circuit breaker on control panel
Communication Ethernet
Control System  
Standard configuration Fully automatic, one-button on/off automatic fault detection system
E-Stop preloading
On-line hydrogen leak detection system /
remote alarm Type C relay, 5A, 250V, 150W max. Rated
Remote Shutdown Safety circuit trip
External machine parameters  
Dimensions, W x D x H Products 71 "x 32" x 75 "/180 cm x 81 cm x 191 cm
Transportation 81 "x 41" x 85 "/206 cm x 104 cm x 216 cm
Note: Height reserved 8cm (3 ") for bracket installation
Weight Products 1500 lbs / 682 kg 1600 lbs / 727 kg 1700 lbs / 773 kg
Transportation 1776 lbs / 807 kg 1887 lbs / 858 kg 1998 lbs / 908 kg
Protection level IP66 for electrical room. IP43 for process room; upgrade to IP56.
Environmental Requirements-Freeze Protection  
Site selection criteria Indoor, horizontal ± 1 °, relative humidity 0 to 90%, non-condensing, non-hazardous/non-classified environment
Storage/Transport Temperature 5°C to 60°C / 41°F to 140°F
Ambient temperature range 5°C to 50°C / 41°F to 122°F
Latitude Range-Sea Level 2400 m / 7874 ft
Ventilation Adequate ventilation must be provided for non-hazardous areas at a rate that meets the IEC60079-10, zone 2 NE
Safety and Regulation  
Maximum hydrogen storage capacity in pipeline at full yield 0.040 Nm3 @ 15 barg; 0.08 Nm3 @ 30 barg
1.5 SCF @ 15 barg; 2.9 SCF @ 30 barg 0.0036 kg @ 15 barg; 0.0069 kg @ 30 barg
Cabinet ventilation environment NFPA 69 and EN 1127-1, clause 6.2.
Ventilation fan up to 28 Nm3/min (1000 ft3 / min) to draw fresh air
Noise at 1 meter dB(A) < 83
Specification CTUV (UL and CSA equivalent), CE (PED, ATEX, LVD, Mach. Dir., EMC), NYFD

Product Consulting

If you have any need, please feel free to contact us

Security verification
Submission
%{tishi_zhanwei}%